DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-4
Suppress Alarm Origination [y] 
5
Figure 5-1.
Multi-Carrier Cabinet ESD Grounding Wrist Strap Jack
Suppress Alarm Origination [y]
When logged in as “craft,” no alarms are reported to INADS. After logging off, 
INADS automatically reactivates, and any unresolved alarms are reported to 
INADS. 
Also, when logged in as “craft,” an automatic logoff of the terminal occurs after 
30 minutes of non-use. At that time, any unresolved alarms are reported to 
INADS. If you are logged in as “craft” at 2 different terminals, the logoff occurs 
when the second terminal remains unused for 30 minutes. 
NOTE:
The test inads-link command functions even if INADS Alarm Origination is 
overridden.
ESD
JACK