Справочник Пользователя для Lucent Technologies Release 6

Скачать
Страница из 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-5
Analog Station or 2-Wire Digital Station Example 
5
Analog Station or 2-Wire Digital 
Station Example
This example is typical of the 2-wire digital stations (603E, 84xx, 94xx, 302C), 
2-wire analog stations (500, 2500, 71xx), analog CO trunks, DID trunks, and 
external alarms. 
The wiring designations for this example are shown in 
Figure 5-4
.
Figure 5-4.
2500-Type Analog Telephone Wiring
1. Choose a peripheral to connect (such as an analog station or 2-wire digital 
station).
2. Choose the port circuit pack, its carrier, slot number, and port. For 
example TN2183 Analog Line, cabinet 1, carrier C, slot 1, port 03.
3. Install cross-connect jumpers to connect the pins from the analog station 
or 2-wire digital station to the appropriate pins on the port circuit pack. 
This pinout information is for the TN2183 Analog Line circuit pack.
4. Administer on the management terminal. See 
DEFINITY Enterprise 
Communications Server Release 6 Administration and Feature 
Description
, for more details.
Figure Notes
1. 2500-Type Analog Station
2. TN2183 Analog Line Circuit Pack 
(Position 1C01)
2500wire RBP 071996
3
28
03
2
T
R
T.3
R.3