DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-6
Analog Tie Trunk Example 
5
Analog Tie Trunk Example
This example shows how to connect analog tie trunk wiring from one DEFINITY 
System to another DEFINITY System.
Figure 5-5.
Analog Tie Trunk Wiring
1. Set the option switches on the port circuit pack (TN760) as described in 
Appendix B, ‘‘Option Switch Settings’’
.
2. Install cross-connect jumpers to connect the named pins from the tie trunk 
circuit pack to the appropriate leads on the external tie trunk. Names of 
the tie trunk leads must be determined from the manufacturer or supplier 
of the external trunk circuit. The example in 
Figure 5-5
 shows a DEFINITY 
System tie trunk connected to a DEFINITY System tie trunk.
3. Administer on the Trunk Group screen of the management terminal. See 
DEFINITY Enterprise Communications Server Release 6 Administration 
and Feature Description
 for more details.
Figure Notes
1. External Trunk or Adapter
2. TN760 Tie Trunk Circuit Pack (Position 1C05)
tie_wire RBP 071796
1
27
26
29
4
30
5
2
28
3
31
6
T.1
R.1
T1.1
R1.1
E.1
M.1
T.2
R.2
T1.2
R1.2
E.2