Справочник Пользователя для Lucent Technologies Release 6

Скачать
Страница из 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-117
Add CallVisor ASAI 
5
Add CallVisor ASAI
Service Interruption
1. Since, if the packet bus is being added, the addition of CallVisor ASAI 
requires a service interruption, notify the customer in advance as to when 
the addition will be carried out.
Disable Alarm Origination
1. Enter change system-parameters maintenance and press 
Enter
2. Set the 
Alarm Origination Activated
 field to n.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate 
alarms, resulting in unnecessary trouble tickets. 
3. For some releases of software, disable 
Cleared Alarm Notification 
and 
Restart Notification
 before submitting the form.
Enter Added Translations
1. On the System-Parameters Customer-Options form, be certain that the 
Calling Party Number/Billing Number (CPN/BN) option is disabled, and 
enable the CallVisor ASAI Interface option. (Either CallVisor ASAI or 
CPN/BN can be enabled on the switch, but not both.)
2. Also, enable the Packet Bus Activated option on the System-Parameters 
Maintenance form. 
3. See 
DEFINITY Enterprise Communications Server Release 6 
Administration and Feature Description
, for details on disabling and 
enabling options on these forms.