DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-119
Add CallVisor ASAI 
5
Install Cables
1. Install cables from cabinet to the MDF as required.
Power Up System
If the packet bus was added:
1. At each EPN, set the main circuit breaker to ON.
2. At the PPN, set the main circuit breaker to ON.
3. The system performs a level 4 reboot, loading the system translations from 
the translation card or tape. Rebooting takes several minutes.
4. After all trouble is cleared, verify the EMERGENCY TRANSFER CONTROL 
switch is set to AUTO. This restores the system to the normal mode.
Enter Added Translations
1. Administer the required translation data using the forms listed under 
“Adjunct/Switch Applications Interface (ASAI)” in 
DEFINITY Enterprise 
Communications Server Release 6 Administration and Feature 
Description
.
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance R6r
Contact INADS to Enable Customer Options and
Verify Alarm Origination
1. Be sure the system is part of the existing INADS database by calling the 
INADS Database Administrator at the Technical Service Center (TSC). 
Verify that INADS can dial into the system and that the system can dial out 
to INADS. 
As part of the system registration process, the INADS Database 
Administrator enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has 
purchased a services contract, the system cannot report any alarm 
to the TSC automatically, causing the TSC to be unable to fulfill the 
services contract.