Справочник Пользователя для John Deere AC1-CG16H

Скачать
Страница из 92
Operator’s Manual  
Symptom 
Problem 
Solution
engine will not start. 
various engine problems. 
Refer to the engine manual 
 
 
accompanying your unit.
noisy operation. 
Loose engine pulley or pump flywheel.  Tighten pulley and or flywheel.
 
Lack of oil in the pump.  
Add correct amount of oil. Check  
 
 
for bearing damage.
 
Carbon deposits on pistons or valves.  Remove cylinder head and inspect.   
 
 
Clean or replace.
 
Bearing, piston or connecting rod failure. STOP THE UNIT!  Contact John Deere  
 
 
customer service.
Pressure drop in air tank or  
Air leaks at connections. 
Allow the unit to build pressure to the 
rapid pressure loss when the 
 
maximum allowed.  Turn off and brush 
unit is shut off.  
 
a soapy water solution onto all 
 
 
connections.  Check connections for  
 
 
air bubbles. Tighten the connections  
 
 
where leaks are present.
 
Air leak in air tank. 
Air tank must be replaced.  Do not  
 
 
attempt to repair air tank!
 
Defective Pilot valve. 
Clean or replace.
Insufficient pressure at air  
Pressure Regulator not turned to 
Adjust Pressure Regulator to proper
 
tool or accessory. 
high enough pressure or defective.  
setting or replace.
 
Restricted air intake. 
Clean or replace Air Intake Filter.
 
Air leaks or restrictions. 
Check for leaks and repair.
 
Hose or hose connections are too  
Replace with larger hose or  
 
 
small or long.  
connectors.
 
Slipping belt. 
Tighten or replace.
 
The unit is not large enough for air  
Check the accessory air requirement. 
 
requirement. 
If it is higher than the CFM or pressure 
 
 
supply to the air compressor, use a  
 
 
larger unit.
 
Restriction in Pilot valve. 
Clean or replace.
Troubleshooting