Справочник Пользователя для Datalogic Scanning PD7100
Datalogic 2 of 5
Product Reference Guide
211
Datalogic 2 of 5 — cont.
Datalogic 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for
Datalogic 2 of 5 Length Control
.
Length 2 is the maximum label length if in
Variable Length
Mode, or the second fixed
length if in
Fixed Length
Mode. The length includes the barcode’s check and data char-
acters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50, or 0 to ignore this length).
The length must be an even number.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 =
05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Program-
ming Mode.
4. Scan the barcode: SELECT Datalogic 2 of 5 LENGTH 2 SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix E, Keypad
, that rep-
resent the length setting which was determined in the steps above. You will hear a
two-beep indication after the last character.
two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Program-
ming Mode.
This completes the procedure. See
Table 28
for some examples of how to set this feature.
Table 28. Datalogic 2 of 5 Length 2 Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
abort and not save the entry string. You can then start again at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to yield
two digits
two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE