AUXILIARY OUTPUTS
The two local auxiliary (AUX) outputs on the rear panel of the CM6800-32X6 can be operated manually from a system keyboard or
automatically in response to an alarm.
Figure 33.  Program Auxiliary Outputs
Latching or Momentary Operation
In the MODE field for each auxiliary, select either LAT or MOM.
Alarm-based Operation
1.
In the MODE field for each auxiliary, select ALM.
2.
In the MON field, select the monitor the auxiliary will follow.
3.
In the DWL field, enter the number of seconds the auxiliary will remain active after there is no longer an alarm displayed on a
system monitor. The alarm is displayed on a monitor until
the alarm is acknowledged manually (if MANUAL is selected in the alarm contact ACK TYPE field),
the alarm contact times out (if AUTO is selected in the alarm contact ACK TYPE field).
Refer to the ACK TYPE description in 
Program an Internal or External Alarm Contact.