If the Gang Count is successfully completed, in addition to displaying “Gang Complete” on the screen, the controller 
provides a gang complete output signal on the spindle’s I/O connector. There are two ways to reset the Gang Count.
1.  Use the dedicated reset palm switch on the Gang Reset Input.
2.  While on the Run Main screen, press 0 (zero) and then the Enter key to reset the Gang Count for the spindle. 
Auto Increment
Auto Increment allows the Insight to move through a specific sequence of fastening Configurations. For example, if 
you have programmed six different Configurations numbered 1 – 6, you can instruct the Insight to perform fastening 
in the sequence 1-4-6 and 2-3-5. By using this parameter to tell the Insight which Configuration to go to next, the 
system continues to step through all programmed Configurations in the Auto Increment chain. The Increment Reset 
parameter tells the Insight which Configuration to use when the Configuration Reset Input is activated.
NOTE: The present Configuration must be completed successfully and the spindle trigger released before the next 
Configuration in the chain is selected.
3.2.3  Start Mode and Config Select
The final two steps in the quick setup procedure are done on the Spindle Setup screen, where you must set the Start 
Mode and Config Select parameters before you begin to operate the Insight controller. For information on setting 
these parameters, see Spindle Setup Screen on page 23.
3.3 
System Setup
3.3.1  Passwords
When your Insight IC-D is first booted up, it is unlocked, allowing full read and write access. This means that there is no 
password protection in place when the system is first booted up. The default password is 1111.
To begin using the password:
1.  Go the Setup menu’s System Setup screen, and scroll down with the arrow keys until you reach the Password 
Logout button at the bottom of the screen.
2.  Press the Enter key to logout.
3.  Return to the System Setup screen and notice that Password Logout button has become Password Login.
4.  Press the Enter key to login.
5.  When password request popup appears, enter the default password, 1111.
6.  Move to the Change Password screen and press Enter to set a new password for the Insight controller.
7.  Enter the current password on the popup screen that appears and press Enter.
8.  Enter a new 4-digit password twice in the data enter boxes provided.
9.  Hit Enter again to set the new password.
10.  Go to the Password Timer parameter on the System Setup screen to change the delay after which password 
protection takes effect. The available increments are 30 sec, 1 min, 2 min, 5 min, 15 min, and 1 hr.
NOTE: Except when the Password Timer parameter is set to “Off,” a Password login is always required after reboot, even 
if the password timer increment period has not passed.
3.3.2  Set Date and Time
The Date and Time parameters found on the System Setup screen include Time Set, Time Mode, Date Set, Time 
Zone, and Date Format. The time is shown in 24-hour clock format. 
To set Date and Time parameters:
1.  Go to the System Setup screen and move to the Time Mode parameter.
2.  Choose either Manual or Auto (NTP). NTP = Network Time Protocol
 
NOTE: If you choose Auto (NTP), the Insight controller has its time setting synchronized through the network time 
protocol on an Ethernet network upon boot up, The Time Set parameter is not available if NTP is selected.
3.  If you select Manual in the Time Mode parameter, go to the Time Set parameter and enter the correct time for 
your location, and skip to step 5.
4.  If you entered Auto (NTP) in the Time Mode parameter, go to the Time Zone parameter and select the correct 
GMT (Greenwich Mean Time) +/- hours for your location.
5.  Move to the Date Format parameter to set the format as either MM/DD/YY or DD/MM/YY.
6.  Finally, move to the Date Set parameter and enter the current date in the format you selected.