Instructions for the installer
 
 
 
 
31 
5.3  Regulation for natural gas 
The hob has been inspected for G20 (2H) natural gas at a pressure of 
20 mbar. To allow the unit to work with this type of gas, perform the same 
operations described in paragraph “5.2  Regulation for LPG”, but choos
the nozzles and regulate the primary air for natural gas, as shown in the 
following table and in paragraph “5.4 Regulation of primary air”. After the 
regulations have been carried out, restore the seals with sealing wax or 
equivalent material. 
 
 
Burner 
 
Rated heating 
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary (1) 
1.05 
73 
380 
Semi-rapid (2) 
1.65 
92 
380 
Average rapid (3) 
2.55 
115 
750 
Large rapid (4) 
3.1 
126 
800 
Triple crown (5) 
3.9 
140 
1400 
Triple crown (6) 
3.3 
130 
1200 
internal (7) 
1.05 
73 
380 
Double crown 
external (7) 
3.9 
140 
1200 
 
 
 
 
5.4  Regulation of primary air 
Referred to distance “X” in mm. 
 
 
BURNER 
G20 
20 mbar 
 
 
G30/G31 
28/37 mbar 
Auxiliary (1) 
1.5 
Semi-rapid (2) 
1.5 
1.5 
 
Average rapid (3) 
1.0 
1.5 
Large rapid (4) 
2.5 
10.0 
Triple crown (5) 
2.0 
3.5 
Triple crown (6) 
2.0 
2.5 
internal (7) 
4.5 
6.0 
Double 
crown 
external (7) 
3.0 
10.0 
 
To identify the burners on your hob, refer to the drawings in point  “6.3 Arrangement 
of burners on hob “