Справочник Пользователя для Cornelius 3

Скачать
Страница из 74
                             
Viper Service Manual
© 2010, IMI Cornelius Inc.
- 53 -
Publication Number: 621360041TBSER
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
M
OTOR
 R
UN
 C
APACITOR
 R
EPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the 
unit between the barrel motors. To replace a run capacitor, perform the proce-
dure in Table 46.
Figure 44. View of Motor Run Capacitors
Table 45
Step
Action
1
Perform the procedure in Steps 1 through 8 of Table 42.
2
 Disconnect the motor from the circuit by unplugging the connector.
3
Remove the motor by removing the four (4) bolts holding the motor to the bar-
rel assembly.
4
Install the replacement motor and connect the connector.
5
Replace the motor seal, scraper blade assembly onto the motor shaft in the 
barrel, as described in Table 42.
6
Reconnect power to the unit.
7
Refill the barrel with product. See “Filling a Barrel” on page 29.
8
When barrel fill is complete, perform a motor calibration. See “Calibrating a 
Barrel Motor
Mounting
Bolts
Foam
Pack
Table 46
Step
Action
1
Disconnect power from the unit.
Motor Run
Capacitors