6.
 
CONNECTION OF REMOTE I/O UNIT 
6.8  Outline of Analog Signal Input Circuit 
 
 
I - 
63
 
6.8  Outline of Analog Signal Input Circuit 
 
The analog signal input circuit can be used only for the FCUA-DX140/DX141. 
 
 
 
     Input circuit 
 
ADC
150
Ω
AI
 
AI*
 
 
 
 
 
     Input conditions 
 
Max. input rating 
±15V 
Resolution 10V/2000 
(5mV) 
Precision 
Within 
±25mV 
AD input sampling time
14.2ms (AI0)/42.6ms (AI1 to 3)