The luminaire should be at least 1m away from the nearest object it is lighting. 
 
 
MOUNTING YOUR LUMINAIRE 
Your luminaire uses a theatre lamp with a grid filament. To avoid premature lamp 
failure it is essential that the luminaire is always mounted so the yoke is horizontal 
and with the lamp base down, i.e. the lamp adjustment knob is at the bottom of the 
rear lamp plate. 
 
 
 
 
Rama 150 Fresnel and PC / Rama 175 Fresnel and PC 
To  mount  on  the  theatre  standard  scaffold  pipe  (48mm  O.D.)  use  a  theatre 
hookclamp (G clamp) (Order Code: 20HC). Your luminaire is supplied with a 
12mm set screw, washers and a nut.  Thread the set screw through the yoke 
from  the  inside,  put  on  a  washer,  then  the  hookclamp,  another  washer  and 
then do up finger tight with the nut.  
To mount on a telescopic stand, reverse the yoke under the luminaire and 
bolt the stand’s spigot onto the 10mm set screw. 
 
Rama 150 FFT Fresnel and PC, Rama 175 FFT HP Fresnel and PC 
To  mount  on  the  theatre  standard  scaffold  pipe  (48mm  O.D.)  use  a  theatre 
hookclamp (G clamp) (Order Code: 20HC). Your luminaire is supplied with a 
FFT  pan  grip  control  to  facilitate  fast  adjustment.  Insert  the  hookclamp  into 
the  top  of  the  FFT  pan  grip  control,  thread  the  12mm  set  screw  provided 
through  the  hookclamp  and  into  the  FFT  pan  grip  control,  and  lock  the 
hookclamp into place with the guides. 
 
SAFETY CHAIN 
 
A  safety  chain  MUST  always  be  used  when  rigging  luminaires  on  bars,  ladders  etc.    
The  Rama  has  an 
integral safety bond that can be retracted into the luminaire when not in use. To use the safety chain, unscrew 
the  safety  chain  locking  clamp  located  on  the  top  of  the  lamphouse,  pull  the  clip  out  from  the  rear  of  the 
lamphouse, and loop the safety chain around the bar fastening the clip onto the safety chain. Be careful to allow 
sufficient  slack  to  enable  the  luminaire  to  be  focused  freely.  To  replace  the  safety  chain,  remove  the  rear 
lamphouse moulding, slide out the safety chain locking clamp, and pull out the safety chain, taking care to retain 
the safety chain loop bar. Reverse the process with a new safety chain.  Replace only with the approved safety 
chains available from Philips Selecon or your distributor. 
 
WARNING: the integrated safety bond will get very hot during use, please take care in handling when the luminaire 
is on.   
Please be careful to allow sufficient slack to allow the luminaire to be focused freely. 
 
FOCUSING 
 
Rama 150 Fresnel and PC, Rama 175 Fresnel and PC 
The variable beam of the Rama is altered by adjusting the position of the lamp / reflector 
assembly  relative  to  the  lens.  Finger  tight  pressure  only  is  necessary  to  lock  the  lamp  / 
reflector assembly off in the chosen positions. A beam angle reference scale is provided 
to prefocus the luminaire if desired. 
When  focusing,  first  spot  the  beam  down,  position  the  luminaire  and  then  flood  the  beam  to  cover  the  area 
required. The beam can then be shaped using the barndoors (Order Code: 20BDSF12). 
Rama 150 FFT Fresnel and PC, Rama 175 FFT HP Fresnel and PC 
The variable beam of the Rama is altered by adjusting the position of the lamp / reflector assembly relative to 
the  lens.  The  Rama  is  suppled  with  an  FFT  focus  assembly  to  facilitate  fast  adjustment.  To  adjust  the  beam 
angle of the Rama, squeeze the focus grip and slide to the position required. Release the focus grip to lock the 
focus.  A beam angle reference scale is provided to prefocus the luminaire if desired. 
When  focusing,  first  spot  the  beam  down,  position  the  luminaire  and  then  flood  the  beam  to  cover  the  area 
required. The beam can then be shaped using the barndoors.