Справочник Пользователя для Philips RAMA FRESNEL & PC RANGE

Скачать
Страница из 4
Version 5: September 2010        © Philips Selecon              All Rights Reserved 
YOKE PIVOT ADJUSTMENT 
The yoke on the Rama range can be positioned anywhere in the channel that runs the length of the luminaire. 
This is useful to achieve the best balance if using a colour changer or other accessory mounted on the front of 
the luminaire, or to fit the luminaire in space restricted positions. 
The yoke balance point is factory set on the lamp house for normal applications.  To move the yoke, loosen the 
M8 bolt at the bottom pivot point of the yoke on the right side of the luminaire.  Release the tilt locking clamp on 
the left side of the luminaire, and slide the yoke to the required position. Check the yoke is evenly positioned on 
each  side  and  tighten  the  M8  bolt,  and  the  tilt  locking  clamp.  To  return  the  yoke  to  its  original  balance  point, 
align the yoke to the balance point marked on the focus reference scale. 
 
PAN AND TILT ADJUSTMENT   
Rama 150 Fresnel and PC, Rama 175 Fresnel and PC 
To pan your luminaire loosen the yoke nut and bolt holding the hookclamp onto the yoke and adjust the yoke as 
required, then  retighten the yoke nut and bolt. 
The  nylock  nut  that  secures  the  yoke  on  the  opposite  side  to  the  tilt  handle  sets  the  tilt  lock  friction.  The  tilt 
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob 
clockwise,  tilt  the  luminaire  to  the  position  required,  and  then  turn  the  tilt  lock  knob  anticlockwise.  A  tilt  angle 
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired. 
 
Please  note  that  as  the  handles  and  integrated  safety  bond  on  the  Rama  range  can  reach  high  temperatures 
depending on the position or orientation of the luminaire, and that gloves should always be worn when focusing. 
 
Rama 150 FFT Fresnel and PC, Rama 175 FFT HP Fresnel and PC 
The Rama is suppled with an FFT pan assembly on the yoke to facilitate fast adjustment. To pan your luminaire 
turn  the  pan  locker  a  ¼  turn  clockwise  and  adjust  the  yoke  as  required,  then  turn  the  pan  locker  a  ¼  turn 
anticlockwise to set the position. A pan angle reference scale is provided on the FFT pan assembly to prefocus 
the luminaire if desired. 
The  nylock  nut  that  secures  the  yoke  on  the  opposite  side  to  the  tilt  handle  sets  the  tilt  lock  friction.  The  tilt 
friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob 
clockwise,  tilt  the  luminaire  to  the  position  required,  and  then  turn  the  tilt  lock  knob  anticlockwise.  A  tilt  angle 
reference scale is provided on the locking clamp disc to prefocus the luminaire if desired. 
 
 ACCESSORIES 
  Suspension Hook Clamp (Order Code: 20HC) 
  Lens Safety Mesh (Order Code: 20SM6) 
  Colour  Frame 
– the luminaire is supplied  with a colour frame  186 x 190mm. Additional colour frames are 
available (Order Code: 20CFRA12). 
  Barndoor (Order Code: 20BDSF12) 
 
EARTH TEST POINT 
There is an earth test point located on the rear housing of the Rama. The earth test point is the silver machine 
screw located on the right side of the rear housing, and is indicated by an earth symbol. To test the earth of the 
Rama, place the test probe on the silver machine screw, and perform the earth test.  
  
CLEANING 
Open the down-swinging door, and clean the lens and/or reflector with a soft lint-free cloth. 
 
This is the only maintenance task, which can be safely carried out by non-approved personnel. 
Refer below 
– Safety & Maintenance note. 
 
SAFETY & MAINTENANCE 
 
Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended 
international  safety  standards.    It  is  your  responsibility  to  maintain  this  luminaire  in  good  and  safe  working 
condition. 
Repairs  should  only  be  carried  out  by  suitably  qualified  persons.    Do  not  operate  the  luminaire  with  cracked 
lens, damaged cables etc. Consult your Philips Selecon distributor for assistance.  Only replace damaged parts 
with authorised Philips Selecon spares. 
N.B.  Luminaire  Cable 
–  your  Philips  Selecon  luminaire  is  fitted  with  a  special  heat-resistant,  flexible  cable, 
replace  with  genuine  Philips  Selecon  spare  part  cable  kit  only 
–  refer  to  your  Philips  Selecon  distributor. 
(Replacement cables are supplied complete with necessary terminal connectors).