Recording – Basic Operations
  
Ch
apt
er 3  Rec
o
rdi
ng and
 P
la
y
bac
k
1
Select the audio channel that you want to record in.
2
Set the AUDIO SELECT (CH-1/CH-2) switch(es) 
corresponding to the audio channel(s) selected in step 
1 to MANUAL.
3
With the AUDIO LEVEL knob on the side control 
panel and the AUDIO LEVEL knob on the front, 
adjust so that the audio level meter shows up to –20 dB 
for a normal input volume.
The input level value of the audio channel 1 is the 
value of the AUDIO LEVEL CH-1 knob on the side 
control panel multiplied by the value of the AUDIO 
LEVEL knob on the front.
The input level value of the audio channel 2 is the 
value of the AUDIO LEVEL CH-2 knob.
When the top bar (0 dB) turns on, the audio level is too 
high. There is no problem if the second bar from the 
top turns on.
To adjust manually the level of audio channel 1 
without using the AUDIO LEVEL knob on the 
front of the camcorder
Set AUDIO CH1 LEVEL to SIDE1 on the AUDIO-1 page 
of the MAINTENANCE menu.
The setting of the AUDIO LEVEL knob on the front of the 
camcorder is disabled.
Setting the Time Data
To set the timecode
The timecode setting range is from 00:00:00:00 to 
23:59:59:29 (hours: minutes: seconds: frames).
(When the frame frequency is 23.98P: from 00:00:00:00 to 
23:59:59:23)
1
Press the DISPLAY/EXPAND button of the LCD 
monitor so that the status display appears.
2
Press the COUNTER/CHAPTER button of the LCD 
monitor to display TCG on the time counter display 
section.
3
Set the PRESET/REGEN/CLOCK switch to PRESET.
4
Set the F-RUN/SET/R-RUN switch to SET.
The first (leftmost) digit of timecode flashes.
5
Use the SEL/SET button (four-way arrow key) to set 
the timecode value including the last (rightmost) digit 
of the timecode.
To reset the timecode value to 00:00:00:00, press the 
RESET button on the right side of the LCD monitor.
When the frame frequency of this unit is 23.98P, a 
timecode frame count can only be set to a multiple of 
4 (0, 4, 8, 12, 16, or 20).
6
Set the F-RUN/SET/R-RUN switch to the desired 
operating mode for the timecode generator.
F-RUN: Free run. The timecode generator keeps 
running.
R-RUN: Recording run. The timecode generator runs 
only while recording.
To set the DF (drop-frame)/NDF (non-drop-frame) 
mode
You can select the drop-frame (DF) mode or non-drop- 
frame (NDF) mode on the TIME CODE page of the 
MAINTENANCE menu.
These bars turn on.
Normal input level
Excessive input level
All bars turn on.
Note
PRESET
F-RUN
REGEN
SET
CLOCK
R-RUN
SUB CLIP
CLIP MENU
SEL/SET
1 2
3
5
4,6