Page 22
FF520
1. To use the keys on the Chart Page, press [MENU] until the Main Menu is show, then
press [CLEAR].
2. To use the keys to control Fish Finder operations, press [MENU] to until the display
shows the Fish Finder Setup, then press [CLEAR].
3.1.3 Sounder Adjustments with Soft Keys (CP175C and CP1000C)
When the Fish Finder full page is displayed, pressing one of the Soft Keys will allow control
of Gain (receiver gain), Noise (Noise threshold), Range (manual depth range), Frequency
(200kHz or 50kHz) and Sensitivity Time Control. If no key is pressed the Soft Keys will
disappear in 5 seconds. To manually hide the Soft Keys, press [CLEAR] .
3.1.3a The G
AIN
 Soft Key
By pressing [G
AIN
] the Gain changes between AUTO GAIN and MANUAL GAIN.
If MANUAL GAIN, use the cursor left/right to adjust it: a bar with the % symbol is displayed
on the screen above the [G
AIN
] label.
If AUTO GAIN, use the cursor left/right to adjust the Gain Offset: a bar with the % symbol
is displayed on the screen above the [G
AIN
] label.
3.1.3b The N
OISE
 Soft Key
Pressing the [N
OISE
] soft key and moving the ShuttlePoint knob to the right or left will
increase or decrease the Noise threshold level..
3.1.3c The R
ANGE
 Soft Key
By pressing [R
ANGE
]  the window switches to the next RANGE status: MANUAL, BOTTOM
LOCK and AUTO.
If MANUAL is selected move the ShuttlePoint knob up or down will adjust the depth vale in
10 Ft steps. To adjust the Shift move the ShuttlePoint knob to the Left or Right.
When BOTTOM LOCK is selected, moving the Shuttlepoint knob up or down to adjust the
Bottom range 10 Ft at a time.
If AUTO RANGE, the range value is set automatically by the FF520 and it cannot be
changed by the user.
3.1.3d The F
REQUENCY
 Soft Key
Pressing the [FREQUENCY] Soft Key toggles the FF520 output frequency between 50,
200kHz and Auto. The current value or Frequency is shown on a window right over the
[F
REQUENCY
] label. The [F
REQUENCY
] is not available when the Fish Finder show 50 and
200kHz Dual page.
3.1.3e The Sensitivity Time Control (STC) Soft Key
The  [STC] changes the STC value between OFF/SHORT/MID/LONG/CUSTOM. The
current value of STC is shown on a window right over the [STC] label. Move the ShuttlePoint
knob left or right will adjust the value.