MAKING LONG EXPOSURES
For exposures between 
1/2
and 
1/10 000
second, no
adjustments are needed for reciprocity law failure.
When exposures longer than 
1/2
second are given,
HP5 Plus, along with other films, needs to be given
more exposure than indicated by a meter. Use the
graph to calculate the increased exposure time which
should be given once the measured time is known.
Measured exposure time (sec)
5
10
15
20
25
30
25
50
75
100
125
150
175
Adjusted exposure time (sec)
CHOOSING THE BEST ILFORD DEVELOPER FOR THE JOB
Manual processing (eg spiral tank, dish/tray, deep tank) and rotary processors
Liquid
Powder
Best overall image quality at meter setting
EI 400/27
ILFOTEC DD-X
ID-11 (stock)
EI 800/30
ILFOTEC DD-X
ID-11 (stock)
EI 1600/33
ILFOTEC DD-X)
MICROPHEN (stock)
EI 3200/36
ILFOTEC DD-X
MICROPHEN (stock)
Finest grain 
ILFOTEC DD-X
PERCEPTOL
Maximum sharpness
ILFOSOL S 
ID-11 (1+3)
Maximum film speed 
ILFOTEC DD-X
MICROPHEN (stock)
One-shot convenience
ILFOSOL S (1+9)
ID-11 (1+1)
ILFOTEC DD-X
MICROPHEN (1+1)
Economy
ILFOTEC LC29 (1+29)
ID-11 (1+3)
MICROPHEN (1+3)
Rapid processing
ILFOTEC HC (1+15)
Replenishable
ILFOTEC HC
ID-11
Machine processing
Dip and dunk
ILFOTEC DD
Best overall image quality (liquid) and long tank life
ID-11
Best overall image quality (powder) and long tank life
ILFOTEC HC
Flexible process time, range of dilutions and economy
Short leader
ILFOTEC RT RAPID
Rapid processing, best overall image quality and
long tank life
ILFOTEC HC
Range of dilutions, flexibility and economy
Roller transport
ILFOTEC RT RAPID
Rapid processing