Справочник Пользователя для Ilford HP5 PLUS HAR1629017

Модели
HAR1629017
Скачать
Страница из 7
35mm film, Rollfilm & Sheet film
ILFORD developer
Dilution
Meter setting (EI)
250/25
320/26
400/27
800/30
1600/33 3200/36
Spiral tank, deep tank, dip and dunk machines (min/20
o
C/68
o
F)
ILFOTEC DD-X
1+4
9
10
13
20
ILFOSOL S
1+9
7
8
1/2
14
1+14
9
1/2
14
ILFOTEC HC
1+15
3
1/2
5
7
1/2
11
1+31
6
1/2
9
1/2
14
ILFOTEC LC29
1+9
3
1/2
5
7
1/2
11
1+19
6
1/2
9
1/2
14
1+29
9
ID-11
stock
7
1/2
10
1/2
14
1+1
13
16
1/2
1+3
20
MICROPHEN
stock
6
1/2
8
11
16
1+1
12
15
1+3
23
PERCEPTOL
stock 13
1+1
18
1+3
25
Non-ILFORD developer
Acufine Acufine
stock
4
1/2
6
1/2
9
1/2
Agfa Refinal
stock
6
8
1/2
Agfa Rodinal
1+25
6
8
1+50
11
Kodak D-76
stock
7
1/2
9
1/2
12
1/2
1+1
11
13
1+3
22
Kodak HC-110
A
2
1/2
3
3/4
5
1/2
9
1/2
B
5
7
1/2
11
Kodak T-Max
1+4
6
1/2
8
9
1/2
11
1/2
Kodak Xtol
stock
8
11
14
19
1+1
12
17
Paterson Acutol
1+10
7
Tetenal Ultrafin
1+10
7
1/2
10
1+20
16
Tetenal Ultrafin Plus
1+4
7
10
13
HP5 Plus
Page 3 of 7
DEVELOPMENT TIMES
The table gives development times for both manual
and machine processing HP5 Plus. These times will
produce negatives of average contrast suitable for
printing in all enlargers. The development times
are intended as a guide and may be altered if a
different result is needed.
For manual processing in spiral tanks and deep
tanks, the development times are based on
intermittent agitation. Where continuous agitation
is used for manual processing (as in a dish/tray or
with some types of developing tank), reduce these
times by up to 15%. For use in rotary processors
without a pre-rinse, reduce the spiral tank
development times by up to 15%. A pre-rinse is
not recommended as it can lead to uneven
processing.