Справочник Пользователя для Sony PDW-F335KL

Скачать
Страница из 188
63
Recording – Basic Operations
  Chapt
er
 3
  Rec
o
rd
ing and
 P
la
y
bac
k
To synchronize the timecode
1
Set the PRESET/REGEN/CLOCK switch to PRESET.
2
Set the F-RUN/SET/R-RUN switch to F-RUN.
3
Press the DISPLAY/EXPAND button of the LCD 
monitor to display TCG on the time counter display 
section.
4
Depending on the frame frequency setting of this unit, 
supply the reference timecode and reference video 
signal shown in the following table to the TC IN 
connector
 1)
 and GENLOCK IN connector, 
respectively. The input reference timecode and 
reference video signal must meet the phase 
relationship requirements of the the SMPTE timecode 
standard. (Excluding the case where the frame 
frequency is 23.98P.)
1) Input to the TC connector, and set the IN/OUT selector switch to IN.
a) More precisely 59.94i
b) More precisely 29.97P
c) External synchronization is not available for 23.97PsF.
This operation synchronizes the internal timecode 
generator with the external timecode. After about 10 
seconds, you can disconnect the external timecode 
without losing the synchronization. However, there 
will be noise on the recorded image if you connect or 
disconnect the timecode signal during recording.
• When the frame frequency of this unit is 23.98P, a 
discrepancy of ±1 frame with the externally locked 
timecode may arise.
• When you finish the above procedure, the internal 
timecode is immediately synchronized with the external 
timecode and the time counter display will show the 
value of the external timecode. However, wait for a few 
seconds until the sync generator stabilizes before 
recording.
• If this unit cannot be genlocked to the reference video 
signal, the internal timecode is not correctly 
synchronized with the external timecode.
Until this unit is genlocked to the input reference video 
signal, the output video signal from this unit may break 
up.
• When the internal timecode generator is set to F-RUN 
mode, the precision of the synchronization may be 
reduced if you turn the POWER switch off and on or 
keep the camcorder turned off for a long time.
About user bits settings during timecode 
synchronization
When the timecode is synchronized, only the time data is 
synchronized with the external timecode value. Therefore, 
the user bits can have their own settings for each 
camcorder. 
To release the timecode synchronization
First disconnect the external timecode, then set the F-
RUN/SET/R-RUN switch to R-RUN. 
To change the power supply from the battery 
pack to an external power supply during 
timecode synchronization
To maintain a continuous power supply, connect the 
external power supply to the DC IN connector before 
removing the battery pack. You may lose timecode 
synchronization if you remove the battery pack first.
Camera synchronization during timecode 
synchronization
During timecode synchronization, the camera is genlocked 
to the reference video signal input from the GENLOCK IN 
connector.
Setting for Special Shooting Cases
Depending on the shooting conditions, set the camcorder 
appropriately referring to the following table.
Frame 
frequency of 
this unit
Acceptable reference 
video signal frame 
frequency (HD or SD)
Acceptable 
timecode
60i
 a)
, 30P
 b)
59.94i
30 frames
50i, 25P
50i
25 frames
23.98P
59.94i
 c)
24 frames
PRESET
F-RUN
REGEN
SET
CLOCK
R-RUN
SUB CLIP
CLIP MENU
SEL/SET
1
2
3
4
Notes