TECHNICAL DATA
 
 
Drawing, see annex 
 
Technical description 
 
Airflow direction 
Air outlet over struts 
Rotational direction 
looking at rotor 
counterclockwise 
Nominal voltage 
12,0 V 
Current consumption 
105 mA 
Power consumption 
1,3 W 
Speed 
2.050 1/min 
Max. free-air flow 
42,0 m3/h 
Weight 
0,095 kg 
Protection class 
III 
Max. torque when 
mounted across both 
mounting flanges 
wire outlet corner: 50 Ncm 
remaining corners: 70 Ncm 
Screw size 
ISO 4762 - M4 degreased, 
without an additional brace and 
without washer 
 
The product is intended for use in sheltered rooms with controlled 
temperature and controlled humidity. Directly exposure to water must 
be avoided. 
 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive 
pollution. The pollution has no negative impact. 
 
Ambient conditions 
 
Permitted ambient temperature 
Transport and storage 
Operation 
-40 °C ... 80 °C 
-20 °C ... 65 °C 
 
Vibration and shock load 
 
At stationary operation: 
 
sinus vibration 
1,0 g; 5 - 500 Hz; 3 x 1 sweep 
(Resonance search run) 
Noise 
0,5 m2/s3, 10 - 50 Hz; +12 
dB/oct f. 5 - 10 Hz; -12 dB/oct f. 
50 - 100 Hz; 3 x 30 min 
Repetitive shock 
Half sine; 5 g, 11 ms; 6 x 100 
shocks 
 
Transport and storage:  
 
Noise 
2,0 m2/s3, 5 - 20 Hz;  -3 dB/oct f. 
20 - 500 Hz; 3 x 30 min 
Thrusts 
Half sine; 18 g, 6 ms; 6 x 100 
shocks 
 
Do not operate your product in the resonance range.  
CONNECTION AND COMMISSIONING
 
 
Connect mechanical parts 
 
 
CAUTION 
Risk of cutting/squashing when 
removing the product from the 
packaging and during mounting. 
 
Grasp the housing and lift the product 
carefully out of the packaging. Avoid 
impact. 
 
Wear safety boots and cut-resistant 
gloves. 
 
 
NOTE 
Risk of damage to electronic 
components. 
 
 
Use ESD protective equipment when 
mounting. 
 
 
 
Connect electrical parts 
 
Connect to the mains after installation. 
 
 
DANGER 
Compliance with the electrical 
installation regulations 
 
 
Observe the connection regulations 
that are valid in your country. (e.g. 
fusing, GFCI) 
 
 
CAUTION 
Electrical voltage 
The product is a built-in 
component and has no switch for 
disconnecting power.
 
 
 
Only connect the product to 
current circuits that can be 
switched off by a switch (all poles 
disconnected). When working on 
the product, secure the 
system/machine in which the 
product is installed against 
switching on again. 
 
 
NOTE 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 
 
Ensure the electromagnetic compatibility of the entire system. 
 
 
Voltage control 
 
 
Speed control via the supply voltage is 
only permitted within the stipulated 
supply voltage range. Speed control via 
PWM of the supply voltage is not 
permitted. 
 
 
 
Requirements: 
 
-  Before connecting the product, ensure that the supply voltage 
corresponds with the product voltage. 
-  Check whether the data on the nameplate corresponds with the 
interface data. 
 
 
Only use cables that are designed for 
the current on the nameplate and the 
corresponding ambient conditions. 
Ensure that the electrical interface data 
is adequately protected (mechanical). 
 
Refer to the nameplate for pin connection. 
 
 
 
 
Colour 
Operation 
Wire 1 
red 
+ UB 
Wire 2 
blue 
- GND 
Wire 3 
violet 
NTC: 
 
 
Check connections 
 