11.  Analog Rule 
Default 06  
 
The analog rule allows the user to set the analog output to follow any of the variables 
listed below.  The variable is selected by entering its number as the Analog Rule. 
 
These are:  
00 -  Flow  A            
06  -  Ratio   
               
01 -  Flow  B            
07  -  Ratio Feedback Mode 
               
02 -  Flow  A+B        
 
08  -  Ratio w/Reset 
               
03 -  Total A            
09  -  Ratio Feedback w/Reset 
               
04 -  Total B            
10  -  A - B Job Total      
               
05 -  Total A+B         
11  -  A - B Flow Rate 
 
NOTE: These variables will be used in the computations as numbers in Engineering 
Units.(ccpm,gals,ozs.etc.) This means that the Decimal Points, if any, will be dropped 
from the numbers.  
 
              
 For instance: 113.7ccpm will be 1137 for computations. 
      
    
12. Unit Number................................................................................................Default 001 
 
   This Variable is used for Serial Communication with a host computer.  It will identify 
each EMO 500 unit if there is more than one on the communication line. For example - 
Unit #1 would be designated 01 & unit #2, 02 ....etc.