The Quick Program Options
  
 
 
 
 
 
 
 
 
 
 
While many programming variables such as KFR or meter selection may only require a 
"one time" setting - others may require some experimentation to find maximum efficiency 
settings.  It may also prove desirable to allow an operator in the field some limited ability 
to make some quick adjustments.  To accommodate these circumstances a method of 
jumping directly into some limited programming functions has been made available.  This 
method is called "Quick Programming"  The functions available are noted in red on the 
top line of keys -F1-F6 Function Keys & 0-1 keys.  
 
F1 ..........................................................................................................................Ideal Ratio 
 
F2 .......................................................................................................................... Gate Time 
     
F3 ............................................................................................................... Ratio Warning % 
 
F4 ................................................................................................................... Ratio Alarm % 
 
F5 .................................................................................................................... Decimal Point 
 
F6 ...................................................................................................................................Enter 
     
0 ......................................................................................................................... Sample Size 
     
1 ...................................................................................................................Specific Gravity
 
    
 
 
 
Connect the Scroll Line Input (Pin 2) and the Common 1 - 5 (Pin 6) of the 15 Pin 
connector on the back panel of the EMO 500 -a momentary contact switch is 
recommended. While this connection is made, simultaneously push any one of the keys 
shown above.  NOTE: This will not work if full programming is enabled. 
 
*NOTE     See Appendix D for a circuit drawing.
 
To activate a Quick Programming Option.