Справочник Пользователя для Advanced Wireless Solutions EMO-500

Скачать
Страница из 40
AW Company 8809 Industrial Drive, Franksville, WI 53126  à web: www.awcompany.com 
 Tel:  262-884-9800  Fax:  262-884-9810 | Email: aw@awcompany.com          
REV. 4                                          10/05                                      EMO-500 Manual.DOC
 
 
11
Programming the EMO 500
 
 
 
As a security precaution, access to the full programming section is only possible when pin 
5 is "enabled".  This can be accomplished by connecting pin 5, on the 15 pin connector, to 
the pin 6 Common (See Appendix D). Next, after first hitting F2, each function key, F1 
through F6, will then allow access to the programming menu indicated immediately 
above it on the red banner strip (The banner strip is labeled 'PROGRAMMING' as 
indicated below). 
 
 
 
ESCAPE 
 
ACCESS 
 
RATIO 
 
LIMITS 
 
METERS 
 
GLOBALS
 
PROGRAMMING
 
 
  
Reminder Note: The other programming functions, indicated in red, on the F1 - F6 and 0 
- 1 keys are activated by the Quick Programming Options which are reviewed on page 8. 
(Quick Programming is provided for immediate access to a few limited programming 
functions only).
 
 
AFTER JUMPERING PIN 5 TO PIN 6 - THE ACCESS SEQUENCE IS AS FOLLOWS: 
 
 
MAIN MENU
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
           
 F2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
OPTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
 
         F3 
 
        F4 
                 F5  
 
       F6                      
              RATIO PRG.         LIMIT PRG.    METER/UNIT PRG.      GLOBALS 
PRG.
   
 
Enable Prog. --> F2 
 
 
 
--> 
--> 
--> 
--> 
 
 
F3 
F4 
F5 
F6 
 
...
... 
...
... 
 
(Access to Ratio Prog) 
(Access to Limit Prog) 
(Access to Meter/Units) 
(Access to Global Prog) 
 
 
IMPORTANT ACCESS IS DENIED TO F3, F4 & F5 UNTIL F2 IS PRESSED FIRST.  
THIS  IS A SECURITY MEASURE TO PREVENT UNINTENTIONAL PROGRAMMING 
CHANGES