Справочник Пользователя для Enviro C-10100

Скачать
Страница из 25
 
3) MAIN BURNERS WILL 
NOT LIGHT 
Make sure gas valve knob is 
in the “ON” position. 
SEE PAGE 8 FIGURE 6. 
Correct if necessary. 
Turn valve to the “ON” 
position. 
Make sure that the “ON-OFF 
THERMO” switch is in the 
“ON” position. 
Turn switch “ON”. 
Make sure that the 
thermostat is “NOT” in the 
lowest position. 
Turn thermostat “UP”. 
Replace damaged wires as 
necessary. Gently squeeze 
connectors with a pair of 
pliers and reinstall wires. 
Make sure that all control 
wires are not damaged, 
broken or frayed and that all 
wire connections are tight. 
Tighten the two screws on 
valve if necessary 
“TP/TP-TH” terminals on 
valve. 
Make sure that the 
thermopile connections are 
tight on the valve. 
Make sure millivolt readings 
from thermopile are within 
manufactures 
specifications. MAKE SURE 
MILLIVOLT READINGS ARE 
CONSTANT. 
SEE PAGE 6 FIGURE 8. 
Place leads of multimeter 
on the “TP/TH-TP” 
terminals on gas valve. If 
the readings are less than 
145mV DC, replace 
thermopile 
Continued on next page. 
Sherwood Industries Ltd.   
 
     ENVIRO   
 
 
PAGE  9