Справочник Пользователя для Enviro C-10100

Скачать
Страница из 25
 
2) PILOT WILL NOT STAY 
LIT 
Use a manometer on the inlet 
side of the valve to measure 
gas pressure.  Adjust inlet 
pressure or contact your gas 
supplier. 
Make sure the gas pressure is 
correct for type of fuel you are 
using. 
SEE PAGE 5 FIGURE 7. 
Thermocouple should be the 
same height as the pilot hood.
Make sure pilot flame is 
engulfing the top 3/8” of the 
thermocouple. 
SEE PAGE 2 FIGURE 2. 
Adjust pilot as required. 
Check for clogged pilot 
injector. 
Make sure thermocouple 
connections on valve are 
tight. 
DO NOT OVER TIGHTEN!!! 
Thermocouple connections 
should be hand tight plu1/4 
turn. 
Clean thermocouple ends 
with Emery cloth or an 
abrasive sponge. 
DO NOT USE A METAL FILE.
Replace if damaged. 
Make sure the thermocouple 
line has no kinks and is clean 
on both ends. Also check the 
thermocouple for damage. 
Using a multimeter, insert 
adapter between valve and 
thermocouple, if the readings 
are less than 2 TO 6 mV DC, 
replace thermocouple. 
SEE PAGE 6 FIGURE 8. 
Make sure the thermocouple 
has proper voltage (DC 
VOLTAGE). 
Sherwood Industries Ltd.   
     
   ENVIRO 
 
 
 
 
PAGE   7