B) DIRECT VENT MODELS 
Check air shutter on the 
burner tube (venturi). 
Adjust air shutter. 
Close until flame sits onto 
the burner ports. 
Seal exhaust tube with high 
temperature silicone. 
Also make sure that 
combustion air pipe is 
sealed. 
Make sure there are no leaks 
in the venting system. 
Make sure the unit is not 
recirculating flue products. 
Check flue for blockage or 
high wind situations. 
Use a manometer to check 
gas outlet (manifold) 
pressure. 
SEE PAGE 5 FIGURE 7. 
Make sure the gas pressure 
is correct for fuel being used.
Make sure the orifice size is 
the same as the rating plate.
Correct if necessary. 
Add a vent restrictor ring. 
SEE OWNERS MANUAL. 
Only if necessary. 