Справочник Пользователя для Enviro C-10100

Скачать
Страница из 25
Check to make sure that the fan is plugged in. 
7) BLOWER DIAGNOSIS 
ALL MODELS 
Make sure the fan control knob is in the “ON” 
position. 
Make sure the two wires are connected to the 
fan temperature sensor. 
Make sure that the two wires are connected to 
the blower. 
Make sure there are no broken, damaged or 
frayed wires. 
Make sure that the fan sensor is secure and that 
it is not damaged. 
Using a supply cord connected 
to the blower, plug the blower 
directly into wall outlet. 
By pass the fan temperature 
sensor with a jumper wire. 
By pass the fan controller with 
 jumper wire. 
a
If the blower does not work, 
replace the fan controller. 
If the blower works, replace 
the fan temperature sensor 
If the blower does not work, 
replace the blower. 
MAKE SURE THAT THE FAN SENSOR IS AT OPERATING 
TEMPERATURE BEFORE TESTING THE FAN CONTROLLER. 
Sherwood Industries Ltd.   
   
   ENVIRO 
 
 
 
PAGE   19