 Reference, Installation, and Operations Manual
Section 6: Meter operation
3-9000-743 Rev S
June 2013
Log record access
 227
6.4.2
Log record access
Due to the Mark III meter’s enhanced log retrieval methods, accessing log records via Modbus 
communication is not supported. All log records (daily, hourly, audit, alarm, and system) are 
accessible via Daniel MeterLink (
) when the optional Log Access feature is 
enabled (
6.5
Optional gas chromatograph interface
The Daniel Mark III Ultrasonic Gas Flow Meter can optionally interface with any Daniel gas 
chromatograph (GC) that supports the SIM2251 mode to read gas property data (such as for 
AGA8, AGA10, energy rate, mass rate, and/or JuniorSonic™ profile correction calculations).   
The following table lists the Gas Chromatograph SIM registers polled by the meter. Also refer to 
Daniel Engineering Specification Part Number ES-17128-005 Rev. B. 
Table 6-15  Gas Chromatograph Sim 2251 Registers
Sim 2251 Register
Description
3034
Stream identifier
3041
Cycle time start - month (1-12)
3042
Cycle time start - day (1-31)
3043
Cycle time start - last two year digits
3044
Cycle time start - hour (0-23)
3045
Cycle time start - minutes (0-59)
3046
GC alarm bitmap 1
3047
GC alarm bitmap 2
3001 - 3016
Component codes
7001 - 7016
Mole fractions for corresponding component codes
7033
BTU (dry)
7034
BTU (sat)
7035
Specific gravity)
7038
Total unnormalized mole percent
7054
BTU (actual)
The gas chromatograph interface is an optional feature that requires both the Option Board 
(for Serial Port C) and a valid GC feature key (