Справочник Пользователя для Emerson Process Management 3420

Скачать
Страница из 398
 Reference, Installation, and Operations Manual
Section 6: Meter operation
3-9000-743 Rev S
June 2013
Archive logs
 231
6.6
Archive logs
The Mark III meter provides five types of data logs (daily, hourly, audit, alarm, and system logs) 
which meets the requirements set forth in the American Gas Association / American Petroleum 
Institute Manual of Petroleum Measurement Standards, Chapter 21.1, Flow Measurement Using 
Electronic Metering Systems (ref. [4]).
Each log type is discussed in detail below (
 through 
) followed by 
instructions on using Daniel MeterLink to read (and optionally save) meter log records 
(
).    
Daily and hourly log data point actions
Five different log data point actions are supported by the daily and hourly logs: snapshot, 
average, flow-gated (average), totalize, and macro as described below:
Snapshot
: causes the data point’s value at the log time to be recorded.
Average
: causes the data point’s average value over the log interval (day or hour) to be 
recorded.
Flow-Gated
: causes the data point’s flow-gated average value over the log interval (day or 
hour) to be recorded. A point’s flow-gated average is the average of its values when the 
flow is above the low-flow cut-off. If the flow does not exceed the cut-off during the 
interval, then the data point’s flow-gated average is the same as its regular (non-flow-
gated) average.
Totalize
: causes the data point’s accumulated value over the log interval (day or hour) to 
be recorded.
Macro
: causes the (boolean) data point’s ‘latched’ value over the log interval (day or hour) 
to be recorded. A (boolean) data point’s latched value indicates if the point was ever TRUE 
during the log interval (where a TRUE value is represented by a 1 and a FALSE value is 
represented by a 0). This allows a group of boolean data points to be grouped into a single 
integer value where each bit represents the latched value of a single boolean data point.
6.6.1
Daily log
The Mark III meter stores a daily log record once per day at the specified contract hour. (Refer to 
 for information on specifying the 
ContractHour data point.)
The meter can store up to 365 daily records. The user can select whether old, unread records 
can be overwritten by new records when the log becomes full via the data point 
DoOverwrit-
eUnreadDailyLog. This point can be modified using the Daniel MeterLink Tools - Edit/Compare 
Configuration
 screen. The default is to overwrite old, unread records. Refer to 
 fo
information on reading records and marking records as read. The data point 
IsDailyLogFull 
indicates whether or not the daily log is full and cannot overwrite old, unread records.
Note that reading log records is an optional feature as described in general in 
 
and in detail in