Справочник Пользователя для Emerson Process Management 3420
Reference, Installation, and Operations Manual
Upgrading a Mark II to a Mark III
3-9000-743 Rev S
June 2013
Inactive chords
309
C.4.8
Inactive chords
The Mark II
ChordInactv
(bitfield) parameter is converted to the Mark III
IsInactiveA...IsInactiveD data points as follows:
C.4.9
AlarmDef
In the Mark II, the
AlarmDef
parameter is used for two purposes:
•
It specifies the number of consecutive batches that a chord must be failed before the
chord failure is indicated in the
chord failure is indicated in the
DataQlty
register.
•
It specifies the number of consecutive batches that all active chords must be without
failure for updating the chord proportions.
failure for updating the chord proportions.
The Mark III provides a separate data point for each of these purposes:
AlarmDef for the first
purpose and
PropUpdtBatches for the second. Since the Mark III batch update period is much
faster than that of the Mark II, the Daniel MeterLink configuration conversion feature does not
modify the Mark III
modify the Mark III
AlarmDef or PropUpdtBatches data points (which should be at default
values). These points’ values can be read and modified via the Daniel MeterLink
Edit/Compare
Configuration
screen.
Table C-1 Mark II chord inactive conversion to Mark III data points
Mark II ChordInactv
Mark III Data Point
Bit Position
Bit Value
Name
Value
0
0
IsInactiveA
0 (FALSE)
1
1 (TRUE)
1
0
IsInactiveB
0 (FALSE)
1
1 (TRUE)
2
0
IsInactiveC
0 (FALSE)
1
1 (TRUE)
3
0
IsInactiveD
0 (FALSE)
1
1 (TRUE)