Справочник Пользователя для Emerson Process Management 3420

Скачать
Страница из 398
 Reference, Installation, and Operations Manual
Section 2: Product overview
3-9000-743 Rev S
June 2013
Electronic specifications
 25
2.4
Electronic specifications
This section discusses the specifications for Daniel Mark III Ultrasonic Gas Flow Meters.
2.4.1
Power specifications
24 VDC nominal, range: 10.4 VDC to 36 VDC
total power consumption less than 8 W
2.4.2
Temperature
Flameproof enclosure and Intrinsically safe base unit refer to 
 for temperature ranges.
Important
 The process temperature must not exceed the operating temperature range of the transducers.
2.4.3
Inputs
one general-purpose digital input
optional analog inputs, one each for pressure and temperature (requires the Option 
Board)
2.4.4
Outputs
two frequency output pairs (4 total)
four digital outputs
one optional analog output (requires the Option Board)
two optional analog outputs (requires the Series 100 Plus Option Board)
2.4.5
Communications
two serial ports (RS-232/RS-485 Full Duplex/RS-485 Half Duplex) with manually switched 
RS-485 terminations
optional third serial port (RS-232/RS-485 Half Duplex) with manually switched RS-485 
terminations (requires the Option Board or Series 100 Plus Option Board)
one optional Ethernet port (10 BaseT)
The optional third serial port can be used as a Modbus master to communicate with a 
Daniel Gas Chromatograph (GC) in Sim 2251 mode.