Справочник Пользователя для Inter-Tel 3000

Скачать
Страница из 139
Inter-Tel 3000 
Administrator’s Manual 
 
 
 85 
•  Select “Name Programming”. 
•  From the extension menu, select the extension you want to name and enter the name as described on 
page 18.  Up to ten characters (including spaces) can be entered for each name. 
•  When the name is entered, select “Confirm”.  You will be presented with the extension menu and can 
continue programming other names. 
Press the speakerphone key to finish programming. 
CLASS-OF-SERVICE 
Each extension can be programmed for a Class-of-Service.  This determines the type of call the extension is 
allowed to dial.  Four tables, which can be programmed with up to fifty codes each, are used to implement 
six Classes-of-Service. 
 
1.  By default, all extensions are in Class 1, that is, they have no restriction placed on them. 
2.  An extension placed in Class 2 is restricted from dialing the codes programmed in Table 2.  (Table 2 
would typically be programmed with the international access code 00). 
3.  An extension placed in Class 3 is restricted from dialing the codes programmed in Tables 2 and 3.  
(Table 3 would typically be programmed with non-local national access codes). 
4.  An extension placed in Class 4 is restricted to dialing internal and emergency (911) calls only. 
5.  An extension can be placed in Class 5 in addition to being in Class 2 or 3. In this case, the codes 
programmed in Table 5 are allowed. 
6.  An extension can be placed in Class 6 in addition to being in Class 1, 2 or 3.  In this case, the codes 
programmed in Table 6 are restricted. 
 
The following table shows the types of restriction for the different Classes-of-Service available: 
Type of restriction 
Table 
Class 
No restriction 
Restrict codes in Table 2 
Table 2 
Restrict codes in Table 2 and 3 
Table 3 
Internal and emergency calls only 
Allowed codes that can be combined with Class 2 or 3 
Allowed 
Table 
Restricted codes that can be combined Class 1, 2 or 3 
Restricted 
Table 
 
Note: The emergency code 911 cannot be restricted. 
 
Note: Both Classes 5 and 6 can be associated with the same extension. 
 
Note: Class 5 cannot be associated with Class 4 extensions. 
 
To Program Class-of-Service Tables 
•  From the programming extension, press the PROGRAM key.    
•  Press the Scroll Down key ( ) until “System Programming” is displayed. 
•  Select “System Programming”. 
•  Enter the System Programming Password and select “System”. 
•  Press the Scroll Down key ( ) until “Class Codes” is displayed. 
•  Select “Class Codes”. 
•  Select the “Table” to which you want to assign codes (Table 2, 3, Allowed Table, or Restricted Table). 
•  Select an “Index Number” and enter the code. 
•  When entering a code, an additional option is given on the display of your digital telephone set. This 
option is the “Any” key, which, when selected, inserts the symbol “X” into the next character of the 
code (number) you are entering. The symbol “X” will represent any number (1 to 0).