Steam Requirements
70420801 (EN)
46
170 Pound Tumble Dryers
Figure 15 
TMB2024N
NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs and 
number of elbows. 
1
Risers 12 in.
 
(305 mm)
6
18 in. Drop (457 mm)
2
Shut-Off Valve
7
Steam Bonnet
3
Check Valve
8
Solenoid Valve (Supplied with machine)
4
Vacuum Breaker (optional)
9
Union
5
Condensate Return Line from Supply Line
10
Trap with Built-In Strainer
TMB2024N
SUPPLY
2
1
9
3
RETURN
2
3
7
10
4
5
8
6
Model
Steam Pressure 
PSI (bar)
Minimum 
Supply Pipe Diameter
Steam Trap Size * 
(Pounds Condensate/Hour)
170S
80-100 (5.3-6.9)
1-1/4 in. NPT
517
*  Based on maximum psi.