Alliance Laundry Systems 907003062 用户手册

下载
页码 52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Adjustments
70420801 (EN)
48
Airflow Switch
The airflow switch is set at the factory for proper 
operation. No adjustment necessary.
The airflow switch operation may be affected by 
shipping tape still in place, lack of make-up air, or an 
obstruction in the exhaust duct. These should be 
checked and the required corrective action taken.
IMPORTANT: Airflow switch vane must remain 
closed during operation. If it opens and closes 
during the drying cycle, this indicates insufficient 
airflow through the tumble dryer. If switch remains 
open, or pops open and closed during the cycle, the 
heating system will shut off. The cylinder and fan 
will continue to operate even though the airflow 
switch is indicating insufficient airflow.
NOTE: To properly mount the airflow switch 
bracket, or in case of a load not drying, the airflow 
switch bracket may need to be checked for proper 
alignment. Be sure the locator pins are securely in 
their respective holes before tightening the bracket 
mounting screws. This will assure proper 
alignment of the airflow switch arm in the channel 
of the airflow switch bracket and prevent binding 
of the arm.
Loading Door Strike
The loading door strike must be adjusted to have 
sufficient tension to hold loading door closed against 
force of load tumbling against it. Proper adjustment is 
when 8-15 pounds (35.6-66.7 N) pull is required to 
open door.
If adjustment is required, refer to Figure 17 and 
proceed as follows:
To adjust, open door, loosen jam nut and turn door 
strike screw in or out as required. Retighten jam nut.
Figure 17 
Loading Door Switch
Loading door switch is factory set; no field adjustment 
necessary.
WARNING
The tumble dryer must not be operated if 
the airflow switch does not operate 
properly. Faulty airflow switch operation 
may cause an explosive gas mixture to 
collect in the tumble dryer.
W072R1
T048I
1
Door Strike
2
Door Latch
3
Jam Nut
2
3
1