ISDN Interfaces
BPTU Installation
Strata CTX I&M        06/04
7-7
ISDN In
terfac
es
BPTU Loop Back Jumper Plugs
The BPTU PCB provides jumper plugs for loop back testing. Loop back tests are described in   
 for switch settings for Loop Back tests.
BPTU Front Panel Indicators
The BPTU PCB provides seven LED indicators to show the status of BPTU: Busy or Idle 
condition, Alarm status, and Synchronization status. 
See 
 for the function of each status LED. 
 shows the LED 
locations.
Ferrite Core
Install the Ferrite core provided with the BPTU PCB, as shown in 
. This 
core is needed to comply with FCC requirements.
BPTU Cabling
The BPTU and RPTU PCBs use the same cabling methods. Refer to 
Table 7-4
BPTU LED Functions
BPTU LEDs
Indication 
FSYNC 
Frame Sync error indication. This LED is not mounted.
MFSYNC
Multi-frame Sync error indication (same with FSYNC)
On = No frame synchronization status
Off = Frame synchronization status
BALM/AIS
AIS indication
On = BPTU is receiving AIS
Off = BPTU is not receiving AIS
YALM/RAI
RAI indication
On = BPTU is receiving RAI
Off = BPTU is not receiving RAI
 LOS
Signaling Loss indication
On = BPTU is not receiving T1 signals
Off = BPTU is receiving T1 signals
 BSY
Busy state indication
On = One or more B-channels are in use. Also when BPTU does 
not receive far end 1.544 mbs carrier signal, BSY is on steady.
Off = All B-channels are idle
PSYNC
Primary synchronization indication
On = BPTU is assigned as the secondary timing PCB. 
Off = BPTU is not assigned as the CLK timing PCB
Flashing = BPTU is extracting T1 CLK
SSYNC
Secondary synchronization indication
Not mounted