RPTU Interface Unit
Circuits per PCB:
24 channels
Interfaces with:
ISDN PRI
Older Version(s):
none
The RPTU provides 24 channels for ISDN PRI service. Network connection using RPTU PRI
interface requires installation of a customer-provided CSU in most locations of the U.S. Refer to
interface requires installation of a customer-provided CSU in most locations of the U.S. Refer to
for CSU installation.
Switches, jumpers, and interface connectors are described in
. The RPTU’s LEDs show
operation status (see
and
and
Testing procedures (local and remote loop back) are in
RPTU Installation
Before installing a RPTU PCB into a Strata CTX system, refer to
:
•
•
(mentioned above in slot assignments)
³
To install an RPTU PCB
1. Set the jumper wire plugs JP1 and JP2 (LB) to the Off position.
2. Turn the Strata CTX system power Off.
3. Insert the RPTU (component side facing right) into the appropriate slot and apply firm, even
pressure to ensure proper seating of connectors.
4. After installing the RPTU, gently pull the PCB outward. If the connectors are properly seated, a
slight resistance is felt.
Note
For cabling information and requirements, refer to
Table 7-5
RPTU Switches, Jumpers, and Connectors
Switches/Jumpers/Connector
Description
SW1 (Line length adjustment switch)
Matches the RPTU impedance to the impedance of the
line (length between the CSU and the RPTU). Refer to
line (length between the CSU and the RPTU). Refer to
.
SW2 (Reset switch)
1
1. If this switch on the Primary Clock source RPTU is pressed, the clock source will automatically revert to the
Secondary Clock source.
Resets or initializes the RPTU firmware. Press this switch
to correct an out-of-service condition, or just prior to
connecting to the Network PRI.
to correct an out-of-service condition, or just prior to
connecting to the Network PRI.
JP1 & JP2 (Loop-back jumpers)
Makes loop-back tests of the cabling between the ISDN
Network switch, CSU, and RPTU.
Network switch, CSU, and RPTU.
J1 8-pin Modular Connector (RJ45)
Connects the RPTU to the CSU/network PRI ISDN line.
J2 6-pin Modular Connector (RJ11)
Connects the RPTU to a terminal or PC to monitor
D-channel data.