Toshiba CTX28 用户手册

下载
页码 495
IP Telephony and QSIG Over IP
CTX IP Troubleshooting
Strata CTX I&M        06/04
9-31
IP T
e
le
pho
n
y
 and Q
S
IG
 
Ov
er
 I
P
2. Log onto the BIPU. At “A.B.C.D login:” prompt, type 
root
 
A.B.C.D login: 
root
(*) A.B.C.D: BIPU IP address programmed in Program 151-FB01. 
3. Display the log files and put them into the text file.
# cat Log0.log
# cat Log0.err
(*) Log0.log contains the all contents of Log0.err.
Check Log0.log/Log0.err for Error Message Output
The format of error message is:
Date
Time
E module-name:error message ex
2003/02/13
17:39:49:340
E CBipulo:Reboot:vp init
³
Display the kernel boot message and put it into the text file 
# dmesg.
Check Whether Message Associated Warnings/Errors Were 
Printed
BIPU Reset
³
If the BIPU resets, find the text string with the implied reset cause.
Table 9-9
BIPU Reset Causes
Reset cause
String in the Log file
Known conditions
Software Reset
Called CPU reset
DSP hardware initialization was failed or timed out.
DSP command execution was failed or timed out.
Any internal process was dead.
Modify the network configuration (IP address, etc.)
BIPU program update
WDT Overflow
WDT Timer Overflow
DSP lock
BIPU is overloaded with network traffic.
Hardware WDT
(PM only)
--
CPU lock
Others
--
--