The detector is less sensitive to motion directly towards 
it and more sensitive to across motion.
  Least Sensitive 
Most Sensitive
Sensor
Motion
Motion
Avoid aiming the sensor at:
•  Objects  that  change  temperature  rapidly,  such  as 
heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.
•  Areas where 
pets or traffic may trigger the control.
•  
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
60 ft. 
(18.3 m)
8 ft. 
(2.4 m)
 
Maximum Range 
Maximum
 
 
Coverage Angle
110°
NOTE:  Sensor has about 1 
1
/
2
 minutes warm up period 
before it will detect motion. When first turned 
on, wait about 1 
1
/
2
 minutes. 
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with 
surrounding temperature].
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . 300  watt  Incandescent  [150 
Max each lamp holder].
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST,  AUTO  and  MANUAL 
MODE
Time Delay  . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T3  150W  halogen  maximum 
120 VAC
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without 
incurring any obligation to incorporate new features in 
products previously sold.
  Loosen the clamp screw in the 
sensor  ball  joint  and  gently 
rotate the sensor.
  Walk  through  the  coverage 
area  noting  where  you  are 
when the lights turn on. Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 
Keep the sensor at 
least 1" (2.4 cm) away from 
the lamps.
  Adjust  the  SENSITIVITY  as 
needed. Too much sensitivity 
may increase false triggering
 
Secure  the  sensor  head’s 
aim by tightening the clamp 
screw.
 Do not overtighten the 
screw.
  Set the amount of TIME you 
want the lights to stay on after motion is detected 
(1, 5, or 10 minutes).
TEST AND ADJUSTMENT
 
Turn on the circuit breaker and light switch.
  Turn the SENSITIVITY (SENS) control to the mid 
position  and  the  ON-TIME  control  to  the  TEST 
position.
Bottom of Sensor
ON-TIME
10 5 1 TEST
MIN  MAX
SENS
Clamp 
Screw
 
Ball 
Joint
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 