ICP-CC488 | Installation Guide | 20.0  
RF Information 
EN | 88 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
 Figure 21:   Connections for CP-5 Master 
Partitioned Codepad and CP-5 Area 
Addressable Codepad 
 
1 – Data 
2 – CLK 
3 – +12 V 
4 – GND 
5 – Master Partitioned 
Codepad 
6 – Addressable Area 
Codepad 
Set the DIP Switches and program these locations for 
the two CP-5 Area Addressable (CP500A) codepads 
to function correctly.  
1.  Set DIP Switch 1 on the back of the remote 
codepad for Area 1 to the ON position (refer to 
Figure 20 on page 87).  
2.  Set DIP Switch 2 on the back of the remote 
codepad for Area 2 to the ON position. 
3.  Select Option 2 in Location 500 (refer to Section 
19.3.1 Partitioning Options 1 on page 85). 
4.  For Output 1, program Location 436 to 6 and 
Location 437 to 1 (refer to page 75). 
 
 
Figure 22:  Connections for Two CP-5 Area 
Addressable Codepads 
 
1 –  Data 
2 –  CLK 
3 –  +12 V
 
4 –  GND 
5 –  Area 1 Codepad 
6 –  Area 2 Codepad
 
20.0  RF Information 
20.1  RF Option Bit 
Location
599 
Default 
Sound siren on RF receiver fail 
Sound siren on RF receiver tamper/jamming 
Unseal zone that fails supervision (if supervision 
enabled) 
Enable RF jamming monitoring 
1 – Sound Siren on RF Receiver Fail 
If this option is selected, the horn speaker, piezo, and 
strobe operate when the RF receiver fails to 
communicate with the control panel. 
2 – Sound Siren on RF Tamper/Jamming 
If this option is selected, the horn speaker, piezo, and 
strobe operate when the tamper switch on the 
receiver becomes open circuit or the receiver picks 
up jamming signals from an RF device. 
4 – Unseal Zone that Fails Supervision 
If a wireless zone device fails to send a signal within 
the RF Supervision Time programmed in Location 
393 (refer to Section 15.8) the codepad zone indicator 
lights as unsealed.