TO FILL THE WATER HEATER 
1.  Close the water heater drain valve by turning the knob clockwise.  If 
alternative water connections are provided but not used, make certain 
they are plugged (i.e. rear connections). 
2.  Open the cold water supply shut-off valve. 
3.  Open several hot water faucets to allow air to escape from the system. 
4.  When a steady stream of water flows from the faucets, the water heater is 
filled.  Close the faucets and check for water leaks at the water heater 
drain valve, combination temperature and pressure relief valve and the 
hot and cold water connections. 
 
TO DRAIN THE WATER HEATER 
Should it become necessary to completely drain the water heater, make sure 
you follow the steps below: 
1.  Rotate the thermostat dial clockwise to the “PILOT LIGHTING” position. 
2.  Rotate and partially depress gas control knob clockwise to the “OFF” 
position. 
3.  Shut off the gas supply to the water heater. 
4.  Close the cold water supply shut-off valve. 
5.  Open the drain valve on the water heater by turning the knob counter-
clockwise.  The drain valve has threads on the end that will allow the 
connection of a standard hose coupling. 
6.  Open a hot water faucet to allow air to enter the system. 
 
To refill the water heater, refer to “To Fill the Water Heater.” 
 
 
 
 
 
 
 
 
General Operation (Standard Pilot Wiring Diagram) continued- 
 
 
WARNING
 
Water heaters are heat producing appliances.  To avoid damage or injury 
there shall be no materials stored against the water heater or vent-air intake 
system, and proper care shall be taken to avoid unnecessary contact 
(especially by children) with the water heater and vent-air intake system.  
UNDER NO CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, 
SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN 
THE VICINITY OF THIS WATER HEATER OR IN ANY LOCATION FROM 
WHICH FUMES COULD REACH THE WATER HEATER.
 
Index