Damper operation: 
 
NOTE 
For Massachusetts residents only: Installation of this vented gas fireplace in the Commonwealth of 
Massachusetts requires the damper to be permanently removed or welded into the fully open position.  In 
addition, a naturally vented gas fireplace may not be installed in a bedroom or bathroom in the 
Commonwealth of Massachusetts. 
 
1.  When damper arm (1) is all the way to the left and locked into position, the damper system is closed.  (Refer to 
Figure 22.) 
2.  Pull damper arm (1) forward and unlock from closed position by swinging damper arm (1) to the right.  (Refer 
to Figure 22.) 
3.  Swing damper arm (1) to the right, forcing into the locked position, to open damper system.  (Refer to Figure 
22.) 
 
WARNING 
Damper must be in open position when appliance main burner is operating.  The damper system must be 
LOCKED into the OPEN position during operation.  If damper is not open the appliance will shut down at 
the pilot.  See lighting instructions if this occurs. 
If damper system is not locked into the open position, the appliance my cause some spillage into the living 
area before the temperature switch can shut the pilot off. 
Do not install a damper device to the appliance.  Only use damper device that comes with the unit 
 
NOTE 
Remove damper instruction tag before operating the unit 
 
 
Figure 22: Damper Operation 
 
 
Hi Temperature Cut Off Disc: 
 
This unit is equipped with a shut off disc that helps prevent spillage due to a down draft.  It also helps prevent 
operation of the unit with damper closed.  The Hi Temp. switch is located on the upper left corner of the fireplace 
opening.  DO NOT OPERATE THE FIREPLACE WITH THE SWITCH BYPASSED