Regency U41-LP3 用户手册

下载
页码 24
5
Regency U41-3 ULTIMATE Gas Fireplace Insert
Fireplace Trim Kit, Part # 610-940, is available.
If the factory built fireplace height is too
low for your Insert, you may remove the
smoke shelf, baffle plate, and damper
plate from the factory built fireplace if
removable without cutting or torching,
as long as these items are saved and are
re-installed in the event that the Insert is
removed.
INSTALLATION INTO
ZERO CLEARANCE
FIREPLACES
The ULTIMATE Gas Inserts are only approved
for installation into the ULTIMATE Gas
Insert Zero Clearance Fireplace Kit, mod-
el # 660-900.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of local
codes, with current CAN/CGA B149 (in
Canada) or the current National Fuel Gas
Code ANSI Z223.1. This appliance MUST be
installed by a qualified gas fitter technician
only.
2) Installation and repair should be done
by a qualified service person.
3) The  appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, etc. It is imper-
ative that control compartments, burners
and circulating air passageways of the
appliance be kept clean and free from
excessive lint from carpeting.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, non-combustible  fire-
place. The appliance and vent should be
enclosed when installed in or passing
through a living area, where children may
come in contact with it.
5) This appliance is Listed for bedroom  instal-
lations when used with a Listed Millivolt
IMPORTANT:
SAVE THESE
INSTRUCTIONS
The Regency Gas Fireplace must be installed
in  accordance with these instructions. Care-
fully read all the instructions in this manual first.
Consult the building authority having jurisdic-
tion to determine the need for a permit prior to
starting the installation.
Note: Failure to follow these instruc-
tions could cause a malfunction of
the heater which could result in
death, serious bodily injury, and/
or property damage.  Failure to
follow these instructions may also
void your fire insurance and/or
warranty.
FOR YOUR SAFETY
This appliance requires air for proper combus-
tion.  Always provide adequate combustion
and ventilation air.  Follow instructions and
information in the current CAN/CGA B149 (in
Canada) or the current National Fuel Gas Code
ANSI Z223.1 (in the USA), regarding require-
ments for combustion and ventilation air.
GAS PIPE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa).
SPECIFICATIONS
Fuel:
Natural gas or Propane
Electrical:
120V  A.C. system.
Fan/Blower:
Variable speed, 125/75 CFM.
Log Sets:
Ceramic fiber, 3 per set.
Vent System: Listed minimum 4" B-Vent  or
listed double thickness
aluminium flex liner.
INSTALLATION INTO A
FACTORY BUILT
FIREPLACE
The ULTIMATE Gas Inserts have been tested
and approved to be vented into any approved
Factory Built Fireplace that will allow the Insert
to physically fit into the firebox. A Factory Built
INSTALLATION
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) This unit is not approved for installation into
a mobile home.
7) Always connect this fireplace to a chimney
and vent to the outside of the building
envelope.  Never vent  to another room or
inside a building.  Make sure that the vent is
properly sized and is of adequate height to
provide the proper draft.
8) Inspect the venting system annually for
blockage and any signs of deterioration.
9) Any safety glass removed for servicing
must be replaced prior to operating the
appliance.
10) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
11) Due to high temperatures, the appliance
should be located out of high traffic areas
and away from furniture and draperies.
Children and adults should be alerted to the
hazards of high surface temperatures,
especially the fireplace glass and gold trims,
and should stay away to avoid burns or
clothing ignition. Young children should be
carefully  supervised when they are in the
same room as the appliance. Clothing or
other flammable material should not be placed
on or near the appliance.
12) WARNING: Failure to position the parts
in accordance with the diagrams in
this manual or failure to use only parts
specifically approved with this appli-
ance may result in property damage
or personal injury.
13) WARNING: Operation of this appliance
when not connected to a properly installed
and maintained venting system or tamper-
ing with the blocked vent shut-off system
can result in carbon monoxide (CO) poison-
ing and possible death.
14) This appliance needs fresh air for safe
operation and must be installed so there are
provisions for adequate combustion and
ventilation air.
MATERIALS
REQUIRED
No electrical power supply is required for the
gas control to operate.  A 120 Volt AC power
Emissions from burning  wood or gas could
contain chemicals known to the State of
California to  cause cancer, birth defects or
other reproductive harm.