Regency U41-3 ULTIMATE Gas Fireplace Insert
cord is hooked up to the fan switch and blower.
Plug 3 wire cord into a suitable receptacle.  Do
not cut the ground terminal off under any
circumstances.
When connected with 120 volts, the appliance
must be electrically grounded in accordance
with local codes, with a current version of CSA
C22.1 (in Canada) or in the absence of local
codes, with the National Electrical Code ANSI/
NFPA 70-1987.
Note: This unit is equipped with a heat
sensor  thermodisc which will
prevent the blower from operat-
ing until the unit reaches the cor-
rect temperature.
INSTALLATION
CHECKLIST
The Regency Gas Insert is installed as listed
below.
1) Unit Location - check Clearances to Com-
bustibles on pages 6 and 7.
2) Make the gas connections and electrical
connection for fan and vent spill switch.
See page 8.
3) Install the flue or liner to the sliding draft
hood. See page 8.
4) Install Venting, page 8. Slide the unit into the
fireplace and level.  Attach draft hood to the
insert.
5) Test gas pressure, page 9. Check aeration,
page 9.
6) Test for flue spillage, page 9.
7) Assemble and install the faceplate and trim.
See page 10.
8) Install the log set. See page 11.
9) Install Doors. See page 11.
10) Install Optional Remote Control,  and Op-
tional Wall Thermostat, page 12.
11) Explain controls to the homeowner.
12) Final check: Before leaving this unit with
the customer, the installer must ensure that
the appliance is firing correctly. This in-
cludes:
a)
Clocking the appliance  to ensure the
correct firing rate.
b)
Adjusting the primary air, if required,
to ensure that the flame does not
carbon.  See page 9.
c)
Ensuring that the appliance is vent-
ing correctly. See page 8.
INSTALLATION
CLEARANCES
I
G
J
H
A
D
B
E
F
C
Top View
Clearances to Combustibles
     From Unit
Sides
A
7.5" / 190 mm
Ceiling
B
35" / 890 mm
Mantel
C(My) 11 / 280 mm
From Surround
Sides
D
2" / 50 mm
Ceiling
E
25.5" / 650 mm
Mantel
F
3" / 75 mm
Min. Alcove Width J
48" / 1120 mm
Mantel Depth
G(Mx) 7.5" / 190 mm
Facing (Mantel Leg)
Side*
K
1" / 25 mm
Top
L
1" / 25 mm
Minimum Fireplace Clearances
The minimum fireplace clearances for the Re-
gency gas fireplace insert are shown in the
following diagrams:
*Max. width  of 1" at 1" from surround, calculate
depth at 45
o
  as shown in the diagram.