Conversion Kit #513-968 from NG to LPG
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
1)  Shut off the gas supply.
2)  Remove the louvers (and bay door if it is 
installed).
3)  Open the fl ush door and remove the door.
4)  Remove the logs and embers (if used).
5)  Remove the 2 screws holding the Burner 
Remove the 2 screws, push Burner Assembly 
to the left and lift out.
6)  Pull off the pilot cap to expose the pilot 
orifi ce.
7)  Unscrew the pilot orifi ce with the allen key; 
then replace with the LPG pilot orifi ce and 
the pilot cap, provided in the kit.
8)  Remove burner orifi ce with a 1/2" wrench. 
Use another wrench to hold on to the elbow 
behind the orifi ce. Discard orifi ce.
Burner Orifi ce
9)  Reinstall new burner orifi ce LPG stamped 
#52 and tighten.
10) Turn control knob to the “OFF” position.
Fig. 1
11) 
R e m o v e   t h e   b l a c k 
protection cap by hand 
from the hi-low knob 
(Fig.1).
Fig.2
14) Flip the screw (Fig. 3).
Fig.4
Fig.3
15) Using the Allen wrench as 
shown in Fig.4, rotate the 
screw clockwise until snug, 
do not overtighten.
12)  Insert a 5/32” or 4mm Allen 
wrench into the hexagonal 
key-way of the screw 
(Fig. 2), rotate it counter-
clockwise until it is free and 
extract it.
13) Check that the screw is 
clean and if necessary 
remove dirt.
Conversion Kit Contains:
Qty. Part 
Description
1   910-037  LPG 
Injector 
   
(Pilot 
Orifi 
ce)
1   
904-390 
Burner Orifi ce #52
1   918-590  Decal 
"Converted 
   
to 
LPG"
1   908-528  Red 
"LPG" 
label
1   904-529  5/32" 
Allen 
Key
1   918-546  Instruction 
Sheet
Assembly to the fi rebox base. Push the 
Burner Assembly to the left and lift out.
WARNING!
Do not over tighten the screw. 
Recommended to
grip the wrench by the short side.
16) Verify that if the conversion is from NG to 
LPG, the screw  must be re-assembled with 
the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
17)  Re - a s s e m b l e   t h e 
black protection cap 
(Fig. 6).
Fig. 6
WARNING!
Also check that the pilot and main 
burner injectors are appropriate for 
the gas type.
19)  Attach clear label "This unit has been 
converted to LPG" near or on the serial 
# decal. 
20) Replace yellow "NG" label with red "LPG" 
label.
21) Check for gas leaks.
22) Check inlet and outlet pressures.
23) Check operation of fl ame control.
24) Check for proper fl ame appearance and 
glow on logs. 
18) Reverse step 2).