Regency Bellavista™ B36X Gas Fireplace
VENTING ARRANGEMENTS 
ALLOWABLE VERTICAL TERMINATIONS
(MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994)
4" X 6 - 5/8" PIPE VENTING ARRANGEMENTS
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
o
 elbows, with 
Rigid Pipe Venting Systems for Propane and Natural Gas.  Two  45
o  
elbows equal to one 90
o
 elbow.  Maximum of four 45
o
 elbows allowed.
Note:  The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor.  
Only rigid pipe may be used when 4" x 6-5/8" is ever used.
•   Vent must be supported at offsets.
•   Firestops are required at each fl oor level and whenever passing through a wall.
•   Maintain clearances to combustibles as listed in the "Clearances" section.
•  Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting 
to 2" opening to 1" opening.
Note:  Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994).
INSTALLATION
Maximum:
35.5
ft.
(10.
m)
8
Minimum
8’
(2.4m)
Min.
49”
(1.2m)
Max. 10’ (3m)(centerline to centerline)
Maximum:
1
9
ft.
(5.8m)
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
V
ertical
Height
(Feet)
32
34
36
38
6
8
Horizontal (Feet)
2
0
4
10
12
16
18
14
Restrictor 1” Open
Restrictor 2” Open
Maximum 12’ Centerline to Centerline