1.5.3
Output
Code
Status
Code
Status
Code
Status
20 OK
33
InvalidOperand
52
OKbutExtControlOFF
30 InvalidType
34
NoEntryData
92
CriticalError
31 InvalidEntry 50
OKbutExtAlarmOFF
32 InvalidValue
51
OKbutMotionOFF
-
50: Although registration succeeded under conditions of type=FTPCondition, Mode=3 and AlarmInMode =2, the Alarm In function is set to “OFF”.
(Ref. Alarm Settings)
-
51:
Although registration succeeded under conditions of type=FTPCondition, Mode=3 and MotionMode=2, the Motion Detection function is set to “OFF”.
(Ref. AlarmSettings)
-
52:Although registration succeeded under conditions of both type=FTPCondition and Mode=4, the Ext. Control In function is set to “OFF”.
(Ref.Alarm Settings)
1.5.4
Example
1) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Default
2) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=FTPCondition&Mode=3&AlarmInMode=2&MotionMode=2
3) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Server-1&Name=FTPs&LoginID=<base64enc>&Password=<basee64enc>
4) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Server-2&Name=FTPs&LoginID=<base64enc>&Password=<basee64enc>
5) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=AttachedPicture&Size=3
6) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=HowToUse&Detail=1
7) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=bySchedule&Interval=5
8) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=byAlarm&Interval=10&AiFileName=_ext_&MdFileName=_mtd_
9) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=byExtControlIn&Interval=10&FileName=extc&Server1Path=/cam/jpge
10) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Accumulation&Mode=2&Interval=10
2) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=FTPCondition&Mode=3&AlarmInMode=2&MotionMode=2
3) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Server-1&Name=FTPs&LoginID=<base64enc>&Password=<basee64enc>
4) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Server-2&Name=FTPs&LoginID=<base64enc>&Password=<basee64enc>
5) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=AttachedPicture&Size=3
6) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=HowToUse&Detail=1
7) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=bySchedule&Interval=5
8) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=byAlarm&Interval=10&AiFileName=_ext_&MdFileName=_mtd_
9) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=byExtControlIn&Interval=10&FileName=extc&Server1Path=/cam/jpge
10) http://10.1.0.1/api/wbsetcamftprecord.cgi?type=Accumulation&Mode=2&Interval=10
1.5.5
Notes
1) If only type=<value> is entered and then <entry>=<value> is not entered, no setting is performed. (type=Default is an exception.)
2) Multiple
2) Multiple
type=<value> cannot be enumerated simultaneously. This API must be started for each type.
3) When LoginID/Password is specified at type=Server-1/2, these must be base64-encoded.
4) When a blank character is included in <value>, it must be URL-encoded.
5) For only entered items, setting is performed. For the other items, their existing values are held.
6) When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.
4) When a blank character is included in <value>, it must be URL-encoded.
5) For only entered items, setting is performed. For the other items, their existing values are held.
6) When OpeLog=No is entered, a log related to API start/end is not output. When it is omitted, it is regarded as OpeLog=Yes.
7) Be very careful that the value of ‘Detail’ entry of type=HowToUse differs from the entry format of WEB setting page.