Lucent Technologies Release 7 用户手册

下载
页码 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-133
ASAI-EPT 
9
Signaling Link Status Test (#626)
This test determines the current status of the signaling link. This test passes if the 
link is "bound" to an endpoint and fails if the link is "not bound."
The definition of the term "bound" for a link depends upon the type of endpoint 
and may depend on the successful completion of procedures at both Layers 2 
and 3 of the protocol. The definition of "bound" for ASAI type of endpoint is:
ASAI adjuncts and BRI endpoints not administered for MIM initialization 
(point-to-point):
For endpoints of this type, the signaling link is "bound" when the link is 
connected at Layer 2 (L2 established).
Table 9-52.
TEST #626 Signaling Link Status Test 
Error 
Code
Test 
Result
Description/ Recommendation
1139
ABORT
The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long UUCSSpp 
command and review the results of the BRI Port Local LAN 
Looparound Test to verify the repair.
1141
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL maintenance documentation.
1144
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the PPN.
2. Execute the test port long UUCSSpp command and review the results 
of the BRI Port Local LAN Looparound Test to verify the repair.
1187
ABORT
The circuit pack, port, or station may have been busied out.
1. Look in the Error Log for Error Type 18 (busied out) for ASAI-BD, 
ASAI-PT, or ASAI-EPT.
2. If this Error Type is present for ASAI-EPT only, then use the release 
station command and run the test again.
3. If this Error Type is present for ASAI-PT and ASAI-EPT, then use the 
release port command and run the test again.
4. If this Error Type is present for ASAI-BD, ASAI-PT, and ASAI-EPT, then 
use the release board command and run the test again.