DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-135
ASAI-PT 
9
ASAI-PT
Unless otherwise stated, all maintenance actions contained in this section apply 
to ASAI-PT and ISDN-BRI ports connected to ASAI adjuncts. This port type is 
administered as an ASAI-BD on the TN800 circuit pack.
The TN800 circuit pack is a PC-based platform that allows interaction of multiple 
applications with DEFINITY. DEFINITY software (Native mode) supports 
emulation of three types of port MOs on this board. The type of ports to be 
emulated are defined by the applications running on the TN800. The TN800 can 
support a maximum of 32 ports (time slots) at a time.
The TN800 connects to the switch through a single slot in the backplane, 
however its width is not limited to one slot. The number of slots occupied by the 
TN800 is supplied by the board during its insertion. The TN800 (Release 5 and 
higher) is 3 slots wide. The blank (reserve) slots are to the left of the functional 
slot.
In non-native mode the TN800 is recognized as TN556, TN2181, TN754, or 
TN746 based on the switch software and the application running on the TN800. 
In non-native mode only one type of port MO runs at any time, and the port type 
depends on the application running on the TN800. If the TN800 fails diagnostics 
in non-native mode, the system’s alarm and error logs would show a failure for 
the board type the TN800 is emulating.
MO Name (in 
Alarm Log
Alarm Level
Initial Command to 
Run
1
1.
Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier where 
the circuit pack is located (for example, 01, 02, ..., and so forth); and pp is the two digit port 
number (01, 02, 03, ...).
Full Name of MO
ASAI-PT
MAJOR
2,3
2.
The alarm level for ASAI adjunct ports may be administered using the set options 
command. The alarm level can be set independently for off-board and on-board alarms to 
WARNING, MINOR, or MAJOR for all ASAI adjunct ports in the system.
3.
All alarming for an ASAI adjunct and off-board alarming for an ASAI port is disabled if the 
ASAI adjunct asks the switch to suspend maintenance. When this occurs, an error and a 
WARNING alarm is logged against the ASAI adjunct. Check the Hardware Error and Alarm 
Logs to see if the adjunct has disabled alarming.
test port UUCSSpp l
ASAI ISDN BRI Port
ASAI-PT
WARNING
test port UUCSSpp l
ASAI ISDN BRI Port