3M 2210 产品宣传页

下载
页码 2
T
ransmitter
 Set Up:
Induction Method
T
ransmitter Operation:
Direct Connect Method
Note:
 Never connect ground to
water pipe or other services in
the area. The return signal may
mislead the trace.
Remove
Near-end
Ground
Suspected
Cable Path
Far-end
Ground 
Red Clip
to Shield
Black Clip to
Ground Rod
T
ransmitter
SIGNAL
DANGER!
Check for stray voltages befor
e attaching transmitter
.
V
oltage gr
eater than 240 volts will damage equipment and
cause personal injury and death.  Follow standar
d
pr
ocedur
es for r
educing 
the 
voltage.
1.
W
ith the transmitter of
f, plug the direct connect
cable into the transmitter front panel jack.
2.
Connect the black clip to the ground rod.
3.
Place
 the ground rod in the earth as far from the 
near
end connection as the leads will allow
, at a 90–
degree
 angle to the suspected cable path.
4.
Remove the near
-end shield bond; connect the red
clip to the shield. 
T
ransmitter
Hinge
Suspected
Cable
 Path
Near-end
Ground
Far-end
Ground
1.
Place
 the transmitter on the ground over the tar
get
cable with the lid hinge in line with the cable path.
Dyna-Coupler
 Method
(Optional Accessories Required)
Suspected
Cable
 Path
T
ransmitter
Note:
 The
 coupler
 jaws
mus
t fully
 clos
e
 for
 signal
trans
mis
s
ion.
SIGNAL
Pedestal
To
T
ransmitter
1.
Plug the Dyna-Coupler  into the cable (optional
accessories). Plug the cable into the transmitter
front panel jack.
2.
Clamp the Dyna-Coupler around the cable below
any bonds just before the cable enters the earth.
Note:
 Dyna-Coupler jaws must be fully closed.

1.
Hold down 
 for 
Battery T
est
 (solid tone=good;
beeping tone=low; no tone=replace batteries).
2.
Press 
 to turn the unit on and select 
Continuity
T
est
 
(solid tone=good ground; beeping tone=
usable ground; no tone=poor ground or no far end
ground).  Both LEDs light continuously during the
continuity test.
3.
Press 
 to apply 
T
racing T
one
 and select the
desired frequency: 577 Hz for direct connect with
far end ground; or 33 KHz for direct connect with no
far end ground, or for use with coupler
, or induction.
LED indicates frequency selection. (This key can also
turn the unit on.)
4.
Press 
 to change output level. Choose 
Normal
output (flashing LED) for locating short to
moderate distances using direct connect method. Use
High
 output
 (solid LED)
 for coupler
, induction, or
direct connect for long distances and deep cables.
5.
When locating is complete, press 
 to turn the
unit of
f.