Check the spray plate is then free to rotate to give the three settings. 
In some winter conditions, when the incoming mains water is particularly cold it may be necessary 
to select the inner or outer spray pattern only. This will ensure correct operation of the shower with 
a slightly lower water flow rate 
 
Note: After use it is normal for some water to drip from the showerhead for a few moments, this 
inhibits scale build up over prolonged use. 
 
What to do if things go wrong 
 
SELF HELP 
 
If the shower is unsatisfactory, make the following checks before calling out the contractor. Any of 
these adjustments could restore the performance 
 
 
a) Water too HOT   
Increase water flow by adjusting the 
temperature control clockwise. 
 
Clean spray plate holes. (Select outer or 
combination spray patterns). 
 
Switch power to MEDIUM setting. 
 
Increase pressure of water supply e.g. fully 
open service valve or stop cock. Check hose is 
not kinked restricting the water flow. 
 
b) Water too COLD 
Decrease water flow by adjusting the 
temperature control anti-clockwise.  
 
Select inner or outer spray patterns only. 
 
Switch power to HIGH setting. 
c) Spray pattern poor 
Clean spray plate and flush heater. (Select 
inner / outer spray pattern). 
 
d) Water goes cold while using shower 
Check water pressure has not fallen so far as 
to let pressure switch cut out, e.g. another tap 
drawing water off.  
Raise position of handset. 
 
e) Broken parts 
Please contact our spares department on  
0870 0102 829.  
Fitting instructions are provided with spares. 
 
 
PROFESSIONAL SERVICE 
 
If the previous checks fail to restore the performance, you should either contact the Redring 
Technical Advisory Service or seek the assistance of a qualified plumber and / or electrician. 
 
The person who installed the shower is probably the best one to repair it and is certainly 
the person to contact if you have a problem in the guarantee period. 
 
The following additional checklist is provided for the benefit of the qualified serviceman. 
 
WARNING – SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE 
REMOVING THE COVER TO MAKE CHECKS.